Solution concept

The panel pair shares one transfer record while each panel retains its own placement confirmation. A single confirmed zone or occupied destination prevents paired-transfer completion. Calibration, grip and PLC sequence are animated as an illustrative simulation.

vision-located targetgrip confirmationphysical transferfinal placement check
Information delivered

The panel pair shares one transfer record while each panel retains its own placement confirmation. A single confirmed zone or occupied destination prevents paired-transfer completion.

Simultaneous panel-pair transfer with a dual vacuum gripperILLUSTRATIVE SIMULATION
Simultaneous panel-pair transfer with a dual vacuum gripper
  1. 01 Image and source
  2. 02 Pose and plan
  3. 03 Grip and lift
  4. 04 Transfer
  5. 05 Release and final check
—

Image both panels and destination nests; establish paired-transfer context.

Illustrative pose offset
—
Illustrative grip confirmation
—
Completed transfers
—

Scenes are illustrative simulations; they are not customer references or performance guarantees.

Need

Two panels on a shared gripper can have different contact states in each vacuum zone. Confirmation for one panel does not validate the pair; source presence, independent grip and destination occupancy need joint tracking.

Solution approach

Locate both panel positions and the dual destination nests. Represent contact and confirmation for each vacuum zone as separate simulated states. Show shared transport in a paired-pick context; lift, lower at the destination, release vacuum and verify both placements.

Process steps

  1. 01

    Image and source

    Image both panels and destination nests; establish paired-transfer context.

  2. 02

    Pose and plan

    Associate panel pose with shared-gripper alignment; check each destination for clearance.

  3. 03

    Grip and lift

    Both vacuum zones make contact; represent grip confirmation separately for each panel.

  4. 04

    Transfer

    Lift and carry the panel pair attached to the shared gripper above the destination.

  5. 05

    Release and final check

    Lower the panels, release vacuum and complete the shared record with both placement confirmations.