Skip to content
E3TAM

Liner, short-shot and tamper-band inspection of plastic closures

Solution concept

Oriented closures are imaged from above and from the side with their openings facing up. Liner position, mould filling and tamper-band bridges are checked; a non-conforming closure is removed by an air nozzle.

ring lightside silhouetteliner position
Information delivered

Liner offset and bridge integrity go to the PLC record. An unsuitable closure is diverted into the reject bin by an air nozzle; top and side images are shown on the operator display.

Liner, short-shot and tamper-band inspection of plastic closuresILLUSTRATIVE SIMULATION
Liner, short-shot and tamper-band inspection of plastic closures
  1. 01 Infeed
  2. 02 Trigger
  3. 03 Acquire
  4. 04 Inspect
  5. 05 Reject
—

Closures advance in one row with openings up.

Liner offset
—
Intact bridges
—

Scenes are illustrative simulations; they are not customer references or performance guarantees.

Need

The internal liner can sit in the shadow of the closure wall. Thin tamper-band bridges are hidden from above; an offset liner and short-shot need to be distinguished from different views.

Solution approach

A photo-sensor triggers the top camera under ring lighting; the liner edge is measured relative to the closure centre. The side camera captures the wall and band silhouette against a backlight; incomplete filling and bridge breaks are compared with the nominal contour.

Process steps

  1. 01

    Infeed

    Closures advance in one row with openings up.

  2. 02

    Trigger

    The photo-sensor registers the closure in the imaging field.

  3. 03

    Acquire

    Top ring-lit and side backlit images are captured.

  4. 04

    Inspect

    The liner edge and band bridges are compared.

  5. 05

    Reject

    The closure with an offset liner is removed by the air nozzle.

Vision system design

Let us assess your application together

We test your sample in our laboratory and report on resolution, optics and lighting selection.

+90 212 275 2280 – 81
Esentepe / İstanbul · İkitelli OSB Laboratory
Request Feasibility